04 system: module housings

Housings for up to twelve single width modules including a power supply, input/output signal connectors, module interconnections, for any practicable module combination.

This cost effective solution to what tends to be a fragmented, application specific area of signal processing allows single function modules to be combined to perform a specific vibration/acoustic measurement task with minimal redundancy.

Particular attention is paid to inter module and power supply screening, switchable signal ground/mains earth connection helps in common mode interference reduction.

PC/04/n*/PS :
mains powered module housings for 2, 4, 6, 8, or 10 single width 04 system modules

PC/04/n*/PS/B :
mains/rechargeable battery powered housings for 2, 4, 6, 8, or 10 single width 04 system modules.

PC/04/n*/PS/XB :
Alternative power sources are catered for to allow operation from 12/28V DC unregulated supplies (Other options on request).

PC/04/n*/PS contains 200/240V, 90/130V, 50/60Hz mains input, ±15V 300mA max O/P regulated power supply, S/C protected, noise/ripple 100µV rms.

PC/04/n/PS/B is mains/battery operated, I/P as above, regulated O/P ±10V, contains
rechargeable 600mA/H batteries.

Input connectors: specify Microdot, BNC coaxial, or Lemo two pole. Coaxial connector
shells are insulated to minimise crosstalk etc.

Output connectors: BNC or specify multiway shielded or barrier terminals. BNC shells are
insulated.